File:RotaryBClickModification.png
Revision as of 10:13, 11 September 2020 by Btisler (talk | contribs) (Do to a design flaw in the MikroBus Rotary B Card which does not allow another SPI device to be present on the SPI Bus. The SoM-IMX6U uses the SPI Bus and the presence of MikroBus Rotary B Card prohibits the SOM from booting. To alleviate this issue,...)
Size of this preview: 800 × 437 pixels. Other resolutions: 320 × 175 pixels | 1,148 × 627 pixels.
Original file (1,148 × 627 pixels, file size: 1.4 MB, MIME type: image/png)
Summary
Do to a design flaw in the MikroBus Rotary B Card which does not allow another SPI device to be present on the SPI Bus.
The SoM-IMX6U uses the SPI Bus and the presence of MikroBus Rotary B Card prohibits the SOM from booting.
To alleviate this issue, the pin labeled “SDO” must be cut
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 10:13, 11 September 2020 | 1,148 × 627 (1.4 MB) | Btisler (talk | contribs) | Do to a design flaw in the MikroBus Rotary B Card which does not allow another SPI device to be present on the SPI Bus. The SoM-IMX6U uses the SPI Bus and the presence of MikroBus Rotary B Card prohibits the SOM from booting. To alleviate this issue,... |